6
RAID 0 (Striping)
This RAID array to be used on New/Blank hard drives.
Striping will destroy existing data on the hard drive.
For Manual Configuration
1. As the BIOS boots press Ctrl+S or F4 when prompted
to enter the RAID BIOS.
2. At the next screen select Create RAID Set, then
press Enter.
3. Select RAID0, then press Enter.
4. Select the number of drives then press Enter.
5. Select Manual configuration then press Enter.
6. Select chunk size from 4k, 8k, 16k, 32k, 64k or 128k,
then press Enter.
7. Select the first drive, press Enter.
8. Select the second drive, press Enter.
9. If applicable select the 3rd and 4th drives pressing
enter after each selection.
10. After selecting the last drive, you are asked Are You
Sure (Y/N)?, press Y to accept.
11. Press Ctrl+E to exit the BIOS.
12. When asked Are you sure to exit (Y/N)?, press Y to
exit.
13. Continue with Fdisk and Format steps as if you
were installing a conventional hard drive.
For Auto Configuration
The default chunk size is 64k when selecting Auto
configuration.
1. As the BIOS boots press Ctrl+S or F4 when prompted
to enter the RAID BIOS.